Wearable medical devices are the key to providing telemedicine services. The patient's ability to monitor his vital signs has an important main effect: increasing the patient's self-awareness of his health, thus preventing possible critical events. This paper presents an error assessment of a new SpO2 and Bpt acquisition system, capable of monitoring both the ECG signal and the PPG signal with medical grade accuracy. The aim of the project is to provide health workers who work with elderly people, non-invasive and easy-to-use devices and the individual citizen, a useful tool for monitoring their well-being. Measuring vital signs using wearable devices is an idea that dates back to the late 1990s, but we are only now seeing a commercial implementation.

I dispositivi medici indossabili sono la chiave per fornire servizi di telemedicina. La capacità del paziente di monitorare i suoi segni vitali ha un imporante effetto principale: aumentare l'autoconsapevolezza del paziente della sua salute, prevenendo così possibili eventi critici. Questo documento presenta una valutazione dell'errore di un nuovo sistema di acquisizione SpO2 e Bpt, in grado di monitorare, sia il segnale ECG, che il segnale PPG con precisione di livello medico. Scopo del progetto è fornire agli operatori sanitari che lavorano con persone anziane, dispositivi non invasivi e di facile utilizzo e al singolo cittadino, uno strumento utile a monitorare il suo stato di benessere. Misurare i segni vitali utilizzando dispositivi indossabili è un'idea che risale alla fine degli anni '90, ma solo ora stiamo assistendo a un'implementazione commerciale.

VALUTAZIONE DELL’ERRORE DI UN SISTEMA DI ACQUISIZIONE SPO2 E BPT

BERNAUDO, GIANNI
2019/2020

Abstract

Wearable medical devices are the key to providing telemedicine services. The patient's ability to monitor his vital signs has an important main effect: increasing the patient's self-awareness of his health, thus preventing possible critical events. This paper presents an error assessment of a new SpO2 and Bpt acquisition system, capable of monitoring both the ECG signal and the PPG signal with medical grade accuracy. The aim of the project is to provide health workers who work with elderly people, non-invasive and easy-to-use devices and the individual citizen, a useful tool for monitoring their well-being. Measuring vital signs using wearable devices is an idea that dates back to the late 1990s, but we are only now seeing a commercial implementation.
2019
EVALUATION OF THE ERROR OF THE SPO2 AND BPT ACQUISITION SYSTEM
I dispositivi medici indossabili sono la chiave per fornire servizi di telemedicina. La capacità del paziente di monitorare i suoi segni vitali ha un imporante effetto principale: aumentare l'autoconsapevolezza del paziente della sua salute, prevenendo così possibili eventi critici. Questo documento presenta una valutazione dell'errore di un nuovo sistema di acquisizione SpO2 e Bpt, in grado di monitorare, sia il segnale ECG, che il segnale PPG con precisione di livello medico. Scopo del progetto è fornire agli operatori sanitari che lavorano con persone anziane, dispositivi non invasivi e di facile utilizzo e al singolo cittadino, uno strumento utile a monitorare il suo stato di benessere. Misurare i segni vitali utilizzando dispositivi indossabili è un'idea che risale alla fine degli anni '90, ma solo ora stiamo assistendo a un'implementazione commerciale.
Wearable devices
Elettrocardiography
Medical device
Remote moitoring
Telemedicine
File in questo prodotto:
Fulltext non presente su UNITESI – Verifica la disponibilità della tesi in formato cartaceo interrogando il Catalogo di Ateneo

I documenti in UNITESI sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14253/92289