Creating the digital anatomical model of the patient turns out to be extremely useful in the pre-operative and pre-operative phases as well as surgical training as it allows to know the relationships between healthy tissues and lesions and the course of the vascular system, analyze anatomical variants and simulate procedures by identifying anatomical landmarks, in order to improve accuracy and avoid damage of nearby structures. The semantic segmentation of the structures of interest is a prerequisite to three-dimensional reconstruction, in particular, the main contribution of the proposed work lies in the intuitive visualization of the vascular systems that supply the kidney and the tumor mass, in order to estimate organ volumes perfused by a vascular branch and to perform a selective and specific clamping, reducing the time interval in which the parenchyma is ischemic in surgical procedures. The approach followed first considers that the structures of interest have variable diameters and numerous bifurcations proceeding from the abdominal aorta to the interlobar arteries. In processing of the 6 Angio-CT volumetric series, the analysis of the second derivatives of the image was carried out using the eigenvalues ​​of the Hessian matrix after having performed convolution with a Gaussian filter whose standard deviation varies in the range of scales in which blood vessels are believed to be. This process has associated to each voxel a measure of the probability of belonging to a blood vessel as an integration of the filter responses on the observation scales and shown in gray scale. Filtering highlighted entirely the intrarenal blood vessels emerged from responses to smaller scales, realizing in fact, their segmentation also contributed to enhancement of larger caliber vessels. Among these there is a sub-range of responses which mask the renal cortex and other anatomical structures of no interest on the background, in addition to the noise, which were included in the filtering. The Hough Transform and Region Growing were used on the image, filtered anisotropically to preserve continuity at the bifurcations, for the automatic segmentation of the aorta and renal arteries that branch off from it. The vertebral column was subsequently isolated with the analysis of the Connected Components. The volume of interest is delimited from the parallelepiped that includes both kidneys segmented by inference of the nnU-Net self-configuring convolutional network. The extraction of the centerline and quantitative features add additional information for the composition of high resolution digital twin, including tortuosity and degree of vascular anastomosis considered a diagnostic decision-making factor as much prognostic for a successful outcome of the surgical procedure.

La creazione del modello anatomico digitale del paziente si rivela estremamente utile nelle fasi pre ed inta-operatorie oltre al training chirurgico in quanto consente di conoscere i rapporti tra i tessuti sani e le lesioni e il decorso dei sistemi vascolari, analizzare le varianti anatomiche e simulare le procedure identificando dei landmarks anatomici, al fine di migliorare la precisione ed evitare il danneggiamento delle strutture vicine. La segmentazione semantica delle strutture di interesse ´e un prerequisito alla ricostruzione tridimensionale, in particolare, il principale contributo del lavoro proposto risiede nella visualizzazione intuitiva dei sistemi vascolari che irrorano il rene e la massa tumorale, al fine di stimare i volumi d’organo perfusi da un branch vascolare per poter realizzare un clampaggio selettivo e specifico, riducendo l’intervallo di tempo in cui il parenchima è ischemico nelle procedure chirurgiche. L’approccio seguito considera dapprima che le strutture di interesse hanno diametri variabili e numerose biforcazioni procedendo dall’aorta addominale fino alle arterie interlobari. Nell’elaborazione delle 6 serie volumetriche Angio-CT è stata svolta l’analisi delle derivate seconde dell’immagine mediante gli autovalori della matrice Hessiana dopo aver eseguito la convoluzione con un filtro gaussiano la cui deviazione standard varia nel range di scale in cui si ritiene trovarsi i vasi sanguigni. Questo processo ha associato ad ogni voxel una misura della probabilità di appartenenza ad un vaso sanguigno come integrazione delle risposte al filtro sulle scale di osservazione e riportata in scala di grigio. Il filtraggio ha evidenziato interamente i vasi sanguigni intrarenali emersi dalle risposte alle scale più piccole, realizzando di fatto la loro segmentazione, inoltre ha contribuito all’enhancement dei vasi di calibro maggiore. Tra queste esiste un sotto-intervallo di risposte che mascherano la corteccia renale e altre strutture anatomiche di non interesse sul background, oltre al rumore, che sono state incluse nel filtraggio. E' stata impiegata la Trasformata di Hough e il Region Growing sull’immagine, filtrata anisotropicamente per preservare la continuit´a in corrispondenza delle biforcazioni, per la segmentazione automatica dell’aorta e delle arterie renali che da essa si diramano. Successivamente è stata isolata la colonna vertebrale con l’analisi delle Componenti Connesse. Il volume di interesse è delimitato dal parallelepipedo che include entrambi i reni segmentati mediante l’inferenza della rete convoluzionale autoconfigurante nnU-Net. L’estrazione delle centerline e delle feature quantitative addiziona ulteriori informazioni per la composizione del gemello digitale ad elevata risoluzione, tra cui la tortuosità e il grado di anastomosi vascolare ritenuto fattore di decision-making diagnostico quanto prognostico per un buon esito della procedura chirurgica.

STUDIO, PROGETTAZIONE E IMPLEMENTAZIONE DI UN ALGORITMO PER LA SEGMENTAZIONE DEI VASI SANGUIGNI RENALI PER LA PIANIFICAZIONE E IL TRAINING CHIRURGICO SUL DIGITAL TWIN DEL PAZIENTE

PRUNELLA, MICHELA
2021/2022

Abstract

Creating the digital anatomical model of the patient turns out to be extremely useful in the pre-operative and pre-operative phases as well as surgical training as it allows to know the relationships between healthy tissues and lesions and the course of the vascular system, analyze anatomical variants and simulate procedures by identifying anatomical landmarks, in order to improve accuracy and avoid damage of nearby structures. The semantic segmentation of the structures of interest is a prerequisite to three-dimensional reconstruction, in particular, the main contribution of the proposed work lies in the intuitive visualization of the vascular systems that supply the kidney and the tumor mass, in order to estimate organ volumes perfused by a vascular branch and to perform a selective and specific clamping, reducing the time interval in which the parenchyma is ischemic in surgical procedures. The approach followed first considers that the structures of interest have variable diameters and numerous bifurcations proceeding from the abdominal aorta to the interlobar arteries. In processing of the 6 Angio-CT volumetric series, the analysis of the second derivatives of the image was carried out using the eigenvalues ​​of the Hessian matrix after having performed convolution with a Gaussian filter whose standard deviation varies in the range of scales in which blood vessels are believed to be. This process has associated to each voxel a measure of the probability of belonging to a blood vessel as an integration of the filter responses on the observation scales and shown in gray scale. Filtering highlighted entirely the intrarenal blood vessels emerged from responses to smaller scales, realizing in fact, their segmentation also contributed to enhancement of larger caliber vessels. Among these there is a sub-range of responses which mask the renal cortex and other anatomical structures of no interest on the background, in addition to the noise, which were included in the filtering. The Hough Transform and Region Growing were used on the image, filtered anisotropically to preserve continuity at the bifurcations, for the automatic segmentation of the aorta and renal arteries that branch off from it. The vertebral column was subsequently isolated with the analysis of the Connected Components. The volume of interest is delimited from the parallelepiped that includes both kidneys segmented by inference of the nnU-Net self-configuring convolutional network. The extraction of the centerline and quantitative features add additional information for the composition of high resolution digital twin, including tortuosity and degree of vascular anastomosis considered a diagnostic decision-making factor as much prognostic for a successful outcome of the surgical procedure.
2021
STUDY, DESIGN AND IMPLEMENTATION OF RENAL BLOOD VESSEL SEGMENTATION ALGORITHM FOR TRAINING AND SURGICAL PLANNING ON THE PATIENT'S DIGITAL TWIN
La creazione del modello anatomico digitale del paziente si rivela estremamente utile nelle fasi pre ed inta-operatorie oltre al training chirurgico in quanto consente di conoscere i rapporti tra i tessuti sani e le lesioni e il decorso dei sistemi vascolari, analizzare le varianti anatomiche e simulare le procedure identificando dei landmarks anatomici, al fine di migliorare la precisione ed evitare il danneggiamento delle strutture vicine. La segmentazione semantica delle strutture di interesse ´e un prerequisito alla ricostruzione tridimensionale, in particolare, il principale contributo del lavoro proposto risiede nella visualizzazione intuitiva dei sistemi vascolari che irrorano il rene e la massa tumorale, al fine di stimare i volumi d’organo perfusi da un branch vascolare per poter realizzare un clampaggio selettivo e specifico, riducendo l’intervallo di tempo in cui il parenchima è ischemico nelle procedure chirurgiche. L’approccio seguito considera dapprima che le strutture di interesse hanno diametri variabili e numerose biforcazioni procedendo dall’aorta addominale fino alle arterie interlobari. Nell’elaborazione delle 6 serie volumetriche Angio-CT è stata svolta l’analisi delle derivate seconde dell’immagine mediante gli autovalori della matrice Hessiana dopo aver eseguito la convoluzione con un filtro gaussiano la cui deviazione standard varia nel range di scale in cui si ritiene trovarsi i vasi sanguigni. Questo processo ha associato ad ogni voxel una misura della probabilità di appartenenza ad un vaso sanguigno come integrazione delle risposte al filtro sulle scale di osservazione e riportata in scala di grigio. Il filtraggio ha evidenziato interamente i vasi sanguigni intrarenali emersi dalle risposte alle scale più piccole, realizzando di fatto la loro segmentazione, inoltre ha contribuito all’enhancement dei vasi di calibro maggiore. Tra queste esiste un sotto-intervallo di risposte che mascherano la corteccia renale e altre strutture anatomiche di non interesse sul background, oltre al rumore, che sono state incluse nel filtraggio. E' stata impiegata la Trasformata di Hough e il Region Growing sull’immagine, filtrata anisotropicamente per preservare la continuit´a in corrispondenza delle biforcazioni, per la segmentazione automatica dell’aorta e delle arterie renali che da essa si diramano. Successivamente è stata isolata la colonna vertebrale con l’analisi delle Componenti Connesse. Il volume di interesse è delimitato dal parallelepipedo che include entrambi i reni segmentati mediante l’inferenza della rete convoluzionale autoconfigurante nnU-Net. L’estrazione delle centerline e delle feature quantitative addiziona ulteriori informazioni per la composizione del gemello digitale ad elevata risoluzione, tra cui la tortuosità e il grado di anastomosi vascolare ritenuto fattore di decision-making diagnostico quanto prognostico per un buon esito della procedura chirurgica.
Digital Twin
Surgical Planning
Image-based CAS
Segmentazione
Ricostruzione 3D
File in questo prodotto:
Fulltext non presente su UNITESI – Verifica la disponibilità della tesi in formato cartaceo interrogando il Catalogo di Ateneo

I documenti in UNITESI sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14253/88479