Osseointegrated implantology represents one of the main solutions for replacing missing teeth, offering numerous advantages in terms of functionality and aesthetics. Research in this field has led to significant advances in material optimization, implant design and surgical techniques to ensure long-term success. A crucial aspect for improving the performance of dental implants is structural analysis, which can be carried out using finite element numerical simulation (FEA). This methodology allows you to study in detail the forces acting on the implants and the surrounding bone tissue, allowing you to predict the mechanical behavior and optimize the design of the implants. The present work aims to explore the use of finite element simulation for the analysis of dental implants, focusing on the evaluation of stresses, deformations and possible critical issues in different loading scenarios. In particular, the Inventor software, an advanced tool that allows the mechanical behavior of the systems to be modeled and analyzed with high precision, was used to perform numerical simulations to analyze the stresses and deformations that the systems undergo under certain load conditions. Two types of implants with different dimensions will be examined, with the aim of identifying the most promising solutions to improve durability and resistance. Furthermore, we will discuss the clinical implications of numerical simulations and their potential in refining dental practices, reducing the risks associated with implantology and optimizing long-term outcomes for patients.

L'implantologia osteointegrata rappresenta una delle principali soluzioni per la sostituzione dei denti mancanti, offrendo numerosi vantaggi in termini di funzionalità e estetica. La ricerca in questo campo ha portato a progressi significativi nell'ottimizzazione dei materiali, nella progettazione degli impianti e nelle tecniche chirurgiche, al fine di garantire il successo a lungo termine. Un aspetto cruciale per il miglioramento delle performance degli impianti dentali è l'analisi strutturale, che può essere effettuata mediante la simulazione numerica agli elementi finiti (FEA). Questa metodologia consente di studiare in modo dettagliato le forze che agiscono sugli impianti e sul tessuto osseo circostante, permettendo di prevedere il comportamento meccanico e di ottimizzare il design degli impianti. Il presente lavoro si propone di esplorare l'uso della simulazione agli elementi finiti per l'analisi degli impianti dentali, focalizzandosi sulla valutazione delle sollecitazioni, delle deformazioni e delle possibili criticità nei differenti scenari di carico. In particolare, il software Inventor , strumento avanzato che permette di modellare e analizzare con elevata precisione il comportamento meccanico degli impianti, è stato utilizzato per eseguire le simulazioni numeriche per analizzare le sollecitazioni e le deformazioni che gli impianti subiscono sotto certe condizioni di carico. Saranno esaminati due tipi di impianti aventi dimensioni differenti, con l’obiettivo di identificare le soluzioni più promettenti per migliorare la durata e la resistenza. Inoltre, si discuteranno le implicazioni cliniche delle simulazioni numeriche e il loro potenziale nell'affinare le pratiche odontoiatriche, riducendo i rischi associati all'implantologia e ottimizzando i risultati a lungo termine per i pazienti.

STUDIO BIOMECCANICO DI DUE IMPIANTI DENTALI CON IL METODO AGLI ELEMENTI FINITI

CARONE, MICHELE
2023/2024

Abstract

Osseointegrated implantology represents one of the main solutions for replacing missing teeth, offering numerous advantages in terms of functionality and aesthetics. Research in this field has led to significant advances in material optimization, implant design and surgical techniques to ensure long-term success. A crucial aspect for improving the performance of dental implants is structural analysis, which can be carried out using finite element numerical simulation (FEA). This methodology allows you to study in detail the forces acting on the implants and the surrounding bone tissue, allowing you to predict the mechanical behavior and optimize the design of the implants. The present work aims to explore the use of finite element simulation for the analysis of dental implants, focusing on the evaluation of stresses, deformations and possible critical issues in different loading scenarios. In particular, the Inventor software, an advanced tool that allows the mechanical behavior of the systems to be modeled and analyzed with high precision, was used to perform numerical simulations to analyze the stresses and deformations that the systems undergo under certain load conditions. Two types of implants with different dimensions will be examined, with the aim of identifying the most promising solutions to improve durability and resistance. Furthermore, we will discuss the clinical implications of numerical simulations and their potential in refining dental practices, reducing the risks associated with implantology and optimizing long-term outcomes for patients.
2023
BIOMECHANICAL STUDY OF TWO DENTAL IMPLANTS WITH THE FINITE ELEMENT METHOD
L'implantologia osteointegrata rappresenta una delle principali soluzioni per la sostituzione dei denti mancanti, offrendo numerosi vantaggi in termini di funzionalità e estetica. La ricerca in questo campo ha portato a progressi significativi nell'ottimizzazione dei materiali, nella progettazione degli impianti e nelle tecniche chirurgiche, al fine di garantire il successo a lungo termine. Un aspetto cruciale per il miglioramento delle performance degli impianti dentali è l'analisi strutturale, che può essere effettuata mediante la simulazione numerica agli elementi finiti (FEA). Questa metodologia consente di studiare in modo dettagliato le forze che agiscono sugli impianti e sul tessuto osseo circostante, permettendo di prevedere il comportamento meccanico e di ottimizzare il design degli impianti. Il presente lavoro si propone di esplorare l'uso della simulazione agli elementi finiti per l'analisi degli impianti dentali, focalizzandosi sulla valutazione delle sollecitazioni, delle deformazioni e delle possibili criticità nei differenti scenari di carico. In particolare, il software Inventor , strumento avanzato che permette di modellare e analizzare con elevata precisione il comportamento meccanico degli impianti, è stato utilizzato per eseguire le simulazioni numeriche per analizzare le sollecitazioni e le deformazioni che gli impianti subiscono sotto certe condizioni di carico. Saranno esaminati due tipi di impianti aventi dimensioni differenti, con l’obiettivo di identificare le soluzioni più promettenti per migliorare la durata e la resistenza. Inoltre, si discuteranno le implicazioni cliniche delle simulazioni numeriche e il loro potenziale nell'affinare le pratiche odontoiatriche, riducendo i rischi associati all'implantologia e ottimizzando i risultati a lungo termine per i pazienti.
File in questo prodotto:
File Dimensione Formato  
Carone_tesi.pdf

File consultabile da postazioni biblioteca

Descrizione: pdf della tesi di laurea
Dimensione 3.93 MB
Formato Adobe PDF
3.93 MB Adobe PDF

I documenti in UNITESI sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14253/86666