In this thesis work, an automatic reporting system for surgical navigators dedicated to the synthesis of lateral fractures of the proximal femur was developed. The study involved the implementation of different phases: segmentation of the femur, identification of the features of interest, optimizer for image superimposition, feature extraction and evaluation, in terms of distance, angle and TAD, of the differences between the target and the images to compare. A graphic interface was created to show the results obtained in a clear and orderly manner. The dataset consists of approximately 150 fluoroscopies. The navigator in question is the Atlas navigator produced by the Masmec Biomed company.
In questo lavoro di tesi si è sviluppato un sistema di reportistica automatico per navigatori chirurgici dedicati alla sintesi delle fratture laterali del femore prossimale. Lo studio ha previsto l'implementazione di diverse fasi: segmentazione del femore, identificazione delle features di interesse, ottimizzatore per la sovrapposizione di immagini, estrazione delle features e valutazione, in termini di distanza, angolo e TAD, delle differenze tra le immagini target e le immagini da confrontare. Si è realizzata un'interfaccia grafica per mostrare in maniera chiara ed ordinata i risultati ottenuti. Il dataset è composto da circa 150 fluoroscopie. Il navigatore in oggetto è il navigatore Atlas prodotto dall'azienda Masmec Biomed.
PROGETTAZIONE, SVILUPPO E VALIDAZIONE DI UN SISTEMA DI VALUTAZIONE AUTOMATICA DI PROCEDURE DI SINTESI DI FRATTURE DEL FEMORE SUPPORTATE DA NAVIGATORI CHIRURGICI
SARACINO, ILARIA
2020/2021
Abstract
In this thesis work, an automatic reporting system for surgical navigators dedicated to the synthesis of lateral fractures of the proximal femur was developed. The study involved the implementation of different phases: segmentation of the femur, identification of the features of interest, optimizer for image superimposition, feature extraction and evaluation, in terms of distance, angle and TAD, of the differences between the target and the images to compare. A graphic interface was created to show the results obtained in a clear and orderly manner. The dataset consists of approximately 150 fluoroscopies. The navigator in question is the Atlas navigator produced by the Masmec Biomed company.| File | Dimensione | Formato | |
|---|---|---|---|
|
Tesi_magistrale_Saracino.pdf
File consultabile da postazioni biblioteca
Descrizione: In allegato, l'elaborato finale di tesi per la laurea magistrale in Ingegneria dei Sistemi Medicali
Dimensione
12.8 MB
Formato
Adobe PDF
|
12.8 MB | Adobe PDF |
I documenti in UNITESI sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/20.500.14253/85116