The herby thesis aims to verify the Environmental Minimum Requirement applied to a public building in Monopoli (BA), the nursery “Il Piccolo Principe”. The study of the structure was conducted with BIM method. Starting from the final design drawing of the shell, we created a digital 3d model with the software Autodesk Revit. The energy information were then added to the BIM model, together with the architectural information. The preliminary Energy Analysis Model was studied with Insight360 and Green Building Studio. Thanks to the interoperability of the BIM model, a simplified model was exported in IFC format (Industry Foundation Classes) and then implemented through Termolog plugin. At last, the data extracted through the IFC file were utilized to verify the EMR.
Nel presente lavoro di tesi al fine di verificare i Criteri Ambientali Minimi attraverso la metodologia BIM si è studiata un’opera di pubblica amministrazione del Comune di Monopoli : l'asilo nido “Il Piccolo Principe”. Attraverso gli elaborati grafici del progetto esecutivo dell'involucro si è realizzato un modello 3D informatizzato della struttura con l'ausilio del software Autodesk Revit. Al modello BIM, oltre alle informazioni dei componenti edilizi, sono state associate informazioni energetiche riguardanti i locali della struttura. Il preliminare modello energetico è stato analizzato con i software Insight360 e Green Building Studio. Successivamente, grazie all’interoperabilità della metodologia BIM, si è esportato il modello semplificato, in un file aperto IFC (Industry Foundation Classes) implementabile all’interno del software Termolog. Quest’ultimo è stato utile al fine di ricavare i dati per la verifica dei CAM ( Criteri Ambientali Minimi).
BIM E VERIFICA DEI CRITERI AMBIENTALI MINIMI
VENERE, MARIA ROSARIA
2018/2019
Abstract
The herby thesis aims to verify the Environmental Minimum Requirement applied to a public building in Monopoli (BA), the nursery “Il Piccolo Principe”. The study of the structure was conducted with BIM method. Starting from the final design drawing of the shell, we created a digital 3d model with the software Autodesk Revit. The energy information were then added to the BIM model, together with the architectural information. The preliminary Energy Analysis Model was studied with Insight360 and Green Building Studio. Thanks to the interoperability of the BIM model, a simplified model was exported in IFC format (Industry Foundation Classes) and then implemented through Termolog plugin. At last, the data extracted through the IFC file were utilized to verify the EMR.| File | Dimensione | Formato | |
|---|---|---|---|
|
Bim e Verifica dei Criteri Ambientali Minimi_Maria Rosaria Venere matr.569903.pdf
non disponibili
Descrizione: Nel presente lavoro di tesi, al fine di verificare i Criteri Ambientali Minimi attraverso la metodologia BIM, si è studiata l'opera pubblica l'asilo nido "Il Piccolo Principe".
Dimensione
4.19 MB
Formato
Adobe PDF
|
4.19 MB | Adobe PDF |
I documenti in UNITESI sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/20.500.14253/67390