The thesis was concerned with analyzing the statistics of PGA recorded in some territories of Greece and Turkey in order to compare these values ​​with those provided by the European and National regulations in the same return period. From the analysis of the data it emerged that, as far as the Greek territory is concerned, since the only return period taken into consideration by the local regulation is 475 years, it was not possible to make a comparison between the measured data and the data calculated according to the national standard. On the contrary, for the Turkish territory this was possible and brought interesting results. For example, it was observed that in the return period of about 40 years, the PGA resulting from the stochastic analysis (95% fractile of the statistical sample) of all the recordings of the individual accelerometric stations, is greater than that proposed by the local regulation by 73.9% for the city of Antioch and 77.4% for Gaziantep. This data reveals an unprudential design using the local regulation data. However, in order to establish how much these differences in terms of PGA were actually impactful in the context of structural design, it was decided to design multi-storey and multi-span steel structures, using the stochastic PGA and the standard one. It was possible to observe that the differences, although obviously present, are significantly reduced, settling at approximately 12% of the structural self-weight (parameter assumed as representative of the structural dimensioning).

La tesi si è occupata di analizzare la statistica dei PGA registrati in alcuni territori di Grecia e Turchia al fine di confrontare tali valori con quelli forniti dalla normativa Europea e Nazionale nel medesimo periodo di ritorno. Dall’analisi dei dati è emerso che, per quanto riguarda il territorio greco, poiché l’unico periodo di ritorno preso in considerazione dalla normativa locale è 475 anni, non è stato possibile effettuare un confronto tra i dati misurati e i dati calcolati secondo la norma nazionale. Al contrario per il territorio turco ciò è stato possibile ed ha portato risultati interessanti. Per esempio, è stato osservato che nel periodo di ritorno di circa 40 anni, il PGA derivante dall’analisi stocastica (frattile del 95% del campione statistico) di tutte le registrazioni delle singole stazioni accelerometriche, è maggiore di quello proposto dalla normativa locale del 73,9% per la città di Antiochia e del 77,4% per Gaziantep. Tale dato rileva una non prudenziale progettazione utilizzando i dati di normativa locale. Tuttavia, al fine di stabilire quanto queste differenze in termini di PGA fossero effettivamente impattanti nell’ambito della progettazione strutturale, si è deciso di progettare delle strutture in acciaio a più piani e più campate, utilizzando il PGA stocastico e quello di norma. Si è potuto constatare che le differenze, seppur ovviamente presenti, si riducono notevolmente attestandosi a circa il 12% del peso proprio strutturale (parametro assunto come rappresentativo del dimensionamento strutturale).

STIMA DELL'ACCELERAZIONE DI PICCO DEL SUOLO ATTRAVERSO UN APPROCCIO PROBABILISTICO: GRECIA E TURCHIA , CASI DI STUDIO.

DI GENNARO, DAVIDE
2023/2024

Abstract

The thesis was concerned with analyzing the statistics of PGA recorded in some territories of Greece and Turkey in order to compare these values ​​with those provided by the European and National regulations in the same return period. From the analysis of the data it emerged that, as far as the Greek territory is concerned, since the only return period taken into consideration by the local regulation is 475 years, it was not possible to make a comparison between the measured data and the data calculated according to the national standard. On the contrary, for the Turkish territory this was possible and brought interesting results. For example, it was observed that in the return period of about 40 years, the PGA resulting from the stochastic analysis (95% fractile of the statistical sample) of all the recordings of the individual accelerometric stations, is greater than that proposed by the local regulation by 73.9% for the city of Antioch and 77.4% for Gaziantep. This data reveals an unprudential design using the local regulation data. However, in order to establish how much these differences in terms of PGA were actually impactful in the context of structural design, it was decided to design multi-storey and multi-span steel structures, using the stochastic PGA and the standard one. It was possible to observe that the differences, although obviously present, are significantly reduced, settling at approximately 12% of the structural self-weight (parameter assumed as representative of the structural dimensioning).
2023
PEAK GRUND ACCELERATION ESTIMATION THROUGH PROBABILISTIC APPROACH: GREECE AND TÜRKIYE CASE STUDIES.
La tesi si è occupata di analizzare la statistica dei PGA registrati in alcuni territori di Grecia e Turchia al fine di confrontare tali valori con quelli forniti dalla normativa Europea e Nazionale nel medesimo periodo di ritorno. Dall’analisi dei dati è emerso che, per quanto riguarda il territorio greco, poiché l’unico periodo di ritorno preso in considerazione dalla normativa locale è 475 anni, non è stato possibile effettuare un confronto tra i dati misurati e i dati calcolati secondo la norma nazionale. Al contrario per il territorio turco ciò è stato possibile ed ha portato risultati interessanti. Per esempio, è stato osservato che nel periodo di ritorno di circa 40 anni, il PGA derivante dall’analisi stocastica (frattile del 95% del campione statistico) di tutte le registrazioni delle singole stazioni accelerometriche, è maggiore di quello proposto dalla normativa locale del 73,9% per la città di Antiochia e del 77,4% per Gaziantep. Tale dato rileva una non prudenziale progettazione utilizzando i dati di normativa locale. Tuttavia, al fine di stabilire quanto queste differenze in termini di PGA fossero effettivamente impattanti nell’ambito della progettazione strutturale, si è deciso di progettare delle strutture in acciaio a più piani e più campate, utilizzando il PGA stocastico e quello di norma. Si è potuto constatare che le differenze, seppur ovviamente presenti, si riducono notevolmente attestandosi a circa il 12% del peso proprio strutturale (parametro assunto come rappresentativo del dimensionamento strutturale).
PGA
File in questo prodotto:
File Dimensione Formato  
TESI DI GENNARO.pdf

File consultabile da postazioni biblioteca

Descrizione: In allegato la tesi definitiva
Dimensione 8.82 MB
Formato Adobe PDF
8.82 MB Adobe PDF

I documenti in UNITESI sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14253/66771