The wearable device is a technologically sophisticated electronic device used for the acquisition of real-time information, which can be comfortably worn by the user. In this thesis work, starting from a preliminary study on flex sensors, a flexible wearable electronic device was designed to be applied as a knee pad made of elastic fabric, to detect and monitor knee joint mobility. The functionality of the developed device was subsequently tested by means of experiments carried out by making a subject wear the electronic device. Furthermore, in order to validate this device, a video analysis of the same movement performed during the experimental test was carried out, and the values acquired by the flexible sensor and the movement analysis were then compared. The experimental results obtained showed that the data from the wearable sensor were congruent with those obtained from the video analysis. However, the results show that, in order to make the values obtained comparable, numerous post-processing operations had to be carried out to enable the optimal synchronisation of the results, an aspect that does not guarantee the same accuracy and precision of the output data from the wearable sensor as those obtained from video analysis. For this reason, the flexible device developed cannot be used in the orthopaedic and clinical fields, but it can still be used in the sports field.

Un dispositivo indossabile è un dispositivo elettronico tecnologicamente sofisticato, utilizzato per l’acquisizione di informazioni in tempo reale, il quale può essere direttamente e comodamente indossato dall’utente. In questo lavoro di tesi, partendo da uno studio preliminare sui flex sensors, si è giunti alla progettazione ed alla realizzazione di un dispositivo elettronico indossabile flessibile, applicato al di sopra di una ginocchiera in tessuto elastico, al fine di rilevare e monitorare la mobilità articolare del ginocchio. Il funzionamento del dispositivo sviluppato è stato successivamente testato attraverso delle prove sperimentali effettuate facendo indossare ad un soggetto il dispositivo elettronico realizzato. Inoltre, al fine di validare tale dispositivo, si è effettuata una videoanalisi dello stesso movimento eseguito durante la prova sperimentale ed i valori acquisiti dal sensore flessibile e dall’analisi del movimento sono stati in seguito confrontati. I risultati sperimentali ottenuti hanno mostrato come i dati ricavati dal sensore indossabile siano congruenti con quelli ottenuti dalla videoanalisi. Tuttavia, dai risultati si evince come per poter rendere confrontabili i valori ottenuti, sia stato necessario ricorrere a numerose operazioni di post processing, per permettere la sincronizzazione ottimale dei risultati, aspetto, che non garantisce la stessa accuratezza e precisione dei dati in output dal sensore indossabile rispetto a quelli ottenuti invece con la videoanalisi. Per questo il dispositivo flessibile sviluppato non potrà essere utilizzato in ambito ortopedico e clinico, ma potrà comunque essere usato in ambito sportivo.

PROGETTAZIONE DI UN SISTEMA ELETTRONICO INDOSSABILE PER LO STUDIO DELLA MOBILITÀ ARTICOLARE NELLA FLESSO ESTENSIONE DEL GINOCCHIO

CESTELLI, MARA
2021/2022

Abstract

The wearable device is a technologically sophisticated electronic device used for the acquisition of real-time information, which can be comfortably worn by the user. In this thesis work, starting from a preliminary study on flex sensors, a flexible wearable electronic device was designed to be applied as a knee pad made of elastic fabric, to detect and monitor knee joint mobility. The functionality of the developed device was subsequently tested by means of experiments carried out by making a subject wear the electronic device. Furthermore, in order to validate this device, a video analysis of the same movement performed during the experimental test was carried out, and the values acquired by the flexible sensor and the movement analysis were then compared. The experimental results obtained showed that the data from the wearable sensor were congruent with those obtained from the video analysis. However, the results show that, in order to make the values obtained comparable, numerous post-processing operations had to be carried out to enable the optimal synchronisation of the results, an aspect that does not guarantee the same accuracy and precision of the output data from the wearable sensor as those obtained from video analysis. For this reason, the flexible device developed cannot be used in the orthopaedic and clinical fields, but it can still be used in the sports field.
2021
DESIGN OF A WEARABLE ELECTRONIC SYSTEM FOR THE STUDY OF JOINT MOBILITY IN THE KNEE FLEX EXTENSION
Un dispositivo indossabile è un dispositivo elettronico tecnologicamente sofisticato, utilizzato per l’acquisizione di informazioni in tempo reale, il quale può essere direttamente e comodamente indossato dall’utente. In questo lavoro di tesi, partendo da uno studio preliminare sui flex sensors, si è giunti alla progettazione ed alla realizzazione di un dispositivo elettronico indossabile flessibile, applicato al di sopra di una ginocchiera in tessuto elastico, al fine di rilevare e monitorare la mobilità articolare del ginocchio. Il funzionamento del dispositivo sviluppato è stato successivamente testato attraverso delle prove sperimentali effettuate facendo indossare ad un soggetto il dispositivo elettronico realizzato. Inoltre, al fine di validare tale dispositivo, si è effettuata una videoanalisi dello stesso movimento eseguito durante la prova sperimentale ed i valori acquisiti dal sensore flessibile e dall’analisi del movimento sono stati in seguito confrontati. I risultati sperimentali ottenuti hanno mostrato come i dati ricavati dal sensore indossabile siano congruenti con quelli ottenuti dalla videoanalisi. Tuttavia, dai risultati si evince come per poter rendere confrontabili i valori ottenuti, sia stato necessario ricorrere a numerose operazioni di post processing, per permettere la sincronizzazione ottimale dei risultati, aspetto, che non garantisce la stessa accuratezza e precisione dei dati in output dal sensore indossabile rispetto a quelli ottenuti invece con la videoanalisi. Per questo il dispositivo flessibile sviluppato non potrà essere utilizzato in ambito ortopedico e clinico, ma potrà comunque essere usato in ambito sportivo.
Flex sensor
dispositivo
mobilità articolare
File in questo prodotto:
File Dimensione Formato  
TESI_Cestelli_Definitiva con liberatoria.pdf

File consultabile da postazioni biblioteca

Descrizione: Tesi finale definitiva di Cestelli Mara, con liberatoria firmata
Dimensione 4.1 MB
Formato Adobe PDF
4.1 MB Adobe PDF

I documenti in UNITESI sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14253/64505